Common faults and solutions of leveling machines
Nov 03, 2025
Leave a message
1. Leveling accuracy does not meet requirements
Fault manifestation: After the plate is leveled, there are still problems such as wavy and warping unevenness.
Cause analysis: uneven wear of the rollers leads to inconsistent force on the plate; the leveling machine parameter settings do not match the plate material and thickness.
Solution: Check the roller wear regularly and replace the severely worn rollers in time; re-adjust the roller gap, pressure and other parameters of the leveling machine according to the actual parameters of the plate.
2. Device operation is slow
Fault manifestation: obvious pauses and jams occur during the operation of the leveling machine.
Cause analysis: insufficient lubrication of transmission parts such as chains and gears, resulting in greater friction; debris has entered the interior of the equipment,

3. hindering the normal operation of the parts.
Solution: Add appropriate lubricant to the transmission parts to ensure good lubrication; stop the machine to clean up the debris inside the equipment, and install a protective device at the feed inlet to prevent debris from entering.
4. Motor overheating
Fault manifestation: After the motor has been working for a period of time, the temperature is too high and even overheat protection is triggered.
Cause analysis: Long-term overload operation, exceeding the rated load of the motor; motor cooling fan failure, poor heat dissipation.
Solution: Check the workload of the leveler to avoid overload operation; if the motor cooling fan is damaged, repair or replace it in time, and clean the dust on the motor heat sink to ensure smooth heat dissipation.
5. Electrical control system failure
Fault manifestation: The operation button fails to work, and the equipment cannot run according to the instructions; the display screen data is abnormal or does not display.
Cause analysis: control circuit aging, short circuit or open circuit; controller program error.
Solution: Carefully check the control circuit, repair or replace the damaged circuit; reset the controller program. If the problem is still not solved, contact the manufacturer for program upgrade or repair.